By browsing this website, you acknowledge the use of a simple identification cookie. It is not used for anything other than keeping track of your session from page to page. OK
0

Effectiveness of a custom-fitted flange and local exhaust ventilation (LEV) system in controlling the release of nanoscale metal oxide particulates during reactor cleanout operations

Bookmarks
Article

Methner, Mark M.

International Journal of Occupational and Environmental Health

2010

16

4

475-487

cleaning of workplace ; exhaust devices ; exposure assessment ; industrial process ; materials testing ; safe working methods ; nanomaterials

Risk assessment and risk management

http://www.ijoeh.com/

English

Bibliogr.;Photos

"As the nanotechnology industry expands, facilities engaged in the production and use of engineered nanoscale materials (ENMs) are challenged with determining whether their processes pose a risk for worker inhalation exposure. Although there are neither regulatory exposure limits specific to ENMs nor validated measurement standards for nanomaterials in the workplace, many facilities opt to be proactive in managing uncharacterized ENMs by reducing or eliminating the potential for exposure by controlling their release into the workplace atmosphere. A field study was conducted to evaluate the effectiveness of a portable, HEPA-filtered, local exhaust ventilation system equipped with a custom-fitted flange for controlling the emission of engineered nanoscale metal oxide particulates during reactor cleanout operations. On the basis of the findings of this study, it appears that a properly designed LEV system, coupled with good work practices can be highly effective in controlling nanoscale material emissions during processes of this type."

Paper



Bookmarks